Double Pipe Heat Exchanger Design 2.1.0.2
DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results..etc
Product Specifications
User Rating: | item has less then 1 vote |
|
FileCart Rating | ||
Submitted by: | webbusterz | |
Homepage | Visit Homepage | |
License | Demo | |
Expires | 30 Days | |
Price | $75.00 | |
Downloads | 1,623 | |
OS Support | Windows Install and Uninstall | |
File Name | dhexdemo.exe | |
File Size | 14.21 MB ( 14,553 KB ) | |
Published | Feb 09, 2008 (17 years ago) | |
Updated | Dec 18, 2013 (11 years ago) |
Follow Us!
Latest Searches
Harga tiket renang kampung sawah week day 17 minutes ago
modern warfare 3 mod 2 hours ago
@eromangakasan 2 hours ago
serasa 2 hours ago
kabza de small imithandazo mp3 download 3 hours ago
INTP ? ??? 5 hours ago
que significan la barra verde y azul de el la informacion de recursos del terrirorio en black desert 6 hours ago
Dev Home Preview 7 hours ago
who made parasat 7 hours ago
Popular Searches
2024 297 times
Softperfect 270 times
Database Workbench Pro 258 times
TeraByte Drive Image Backup and Restore 255 times
Elcomsoft Phone Breaker 251 times
Elcomsoft Phone Viewer 232 times
SAM Broadcaster Cloud 223 times
BootIt Collection 223 times
YetiShare File Hosting Script 207 times
Product Details
+Step by step calculation
+Support S.I & English (U.S) Units of measurement.
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Save/Load results
+Export Results to Microsoft Excel Engineering Datasheet
-Calculations-
+Calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.
+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Difference, Number of Hairpins, Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers.
+Duty, Clean and Design Overall heat transfer coefficient calculations
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units & Thermal Capacity ratio calculation.
+Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
-Databases
+Physical properties estimation of pure components for more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included & come as a standalone interface but easily integrated with the software.
+Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!)
+Fouling factors
Requirements: | Windows operating system, 20MB Free space |
Release Info: | New Release on Nov 02, 2012 |
Release Notes: | Added export to Microsoft Excel 97/2003 Engineering datasheet, now you can choose to export to either Microsoft Excel 2007/2010 or older excel versions, Corrected a bug in the loading module causes the software not |
Related Tags: | heat exchanger double pipe hairpin heat exchangers thermal design calculations |
Reviews
Reviews of Double Pipe Heat Exchanger Design 2.1.0.2
You can be the first to write a review of Double Pipe Heat Exchanger Design!Other products submitted by this publisher
Thermal design and sizing calculations of Air cooled heat exchangers. The software will design horizontal induced draft or forced draft units for liquid and gas services and will produce a three page summary of all results and drawing
All Correspondence and Documents Managerkeep a track of all your correspondences and documents that you have stored on your computer or on files. The software is easy to use and have many useful and custom features which allow the user to set reminders,add documents formats and numbering.
ChemEng Economics CalculatorEasy to use software demonstrates the procedures to estimate the net present value of industrial process plants. the calculation involves, fixed capital investment, operating labour,utility costs,raw materials & profits and production costs..etc
Condenser DesignCondenser design (CnD) is a software tool that is made to demonstrate the thermal design calculations of Shell & Tube condensers. The software can design, horizontal condensers, vertical condensers including reflux condensers. Many features....etc
Decanter Sizing CalculatorDecanters are used for liquid-liquid separation when there is a sufficient difference in density between liquids for the droplets to settle. Decanter sizing calculator (DSC) is a software that is built to size horizontal and vertical decanters
Most Viewed Windows Calculators
Shell and Tube Heat Exchanger Design 3.5.0.4
Trades Math Calculator 2.0.1a
Steam Calculator 3.0
Machinist Calculator 7.10.0
Double Pipe Heat Exchanger Design 2.1.0.2
Amortization Schedule Calculator 1.1
EngCalc(Pneumatic)- PocketPC Calculator 2.0
MITCalc Tolerance analysis 1.19
Cutting 3 1.23
Most Downloaded Windows Calculators
Shell and Tube Heat Exchanger Design 3.5.0.4
Double Pipe Heat Exchanger Design 2.1.0.2
Steam Calculator 3.0
ChemMaths 17.1
Cutting 3 1.23
Machinist Calculator 7.10.0
CASC concentration calculator 1.0.2.35
CalculatorX 1.2 .6688
Amortization Schedule Calculator 1.1